Differences between revisions 1 and 9 (spanning 8 versions)
Revision 1 as of 2017-02-11 21:58:59
Size: 1219
Comment:
Revision 9 as of 2017-02-11 23:58:47
Size: 2233
Comment:
Deletions are marked like this. Additions are marked like this.
Line 3: Line 3:
Laminated launch loop rotors will have good magnetic properties and will rapidly disperse and oxidize in the atmosphere after a rotor-release catastrophe. Laminated launch loop rotors will have good magnetic properties and will rapidly disperse and oxidize in the atmosphere after a rotor-release catastrophe. Worst case, thin flakes survive and cut.
Line 5: Line 5:
 . [[ http://metglas.com/products/magnetic_materials/2605SA1.asp | Metglas 2605SA1 ]] looks good, higher temperature than 2605HB1M.
 .
[[ attachment:2605sa1.pdf | datasheet ]] downloaded 2017/02/11 
[[ http://metglas.com/products/magnetic_materials/2605SA1.asp | Metglas 2605SA1 ]] looks good, higher temperature than 2605HB1M. [[ attachment:2605sa1.pdf | datasheet ]] downloaded 2017/02/11
Line 8: Line 7:
||<-2:> '''Metglas 2605SA1''' ||
|| Curie temperature || 395C / 668K ||
|| saturation induction || 1.56 Tesla ||
|| resistivity || 1.3 μΩ-m ||
||
thickness || 23 μm ||
|| density || 7.18 g/m³ ||
|| Tensile Strength || 1 GPa ||
|| Elastic Modulus || 100 GPa ||
|| Thermal Expansion || 7.6 ppm/°C ||
||
Iron || 85 to 95% ||
|| Silicon || 5 to 10% ||
|| Boron || 1 to 5% ||
||<-2> 60 Hz and 1.4 T ||
|| Induction at 80 A/m || ≥1.35 T ||
|| Core Loss || ≤0.17 W/kg ||
||Exciting Apparent Power* || 1.1 (VA/kg) ||
||<-5:> '''Metglas 2605SA1'''                                               ||
|| Curie temperature || 395C / 668K || || saturation induction || 1.56 Tesla ||
|| thickness || 23 μm || || density || 7.18 g/cm³ ||
|| Thermal Expansion || 7.6 ppm/°C || || Iron vaporization temp || 3140 K ||
|| Tensile Strength || 1 GPa || || Elastic Modulus || 100 GPa ||
|| Iron || 85 to 95% || || [[ https://www.cdc.gov/niosh/npg/npgd0344.html | IDLH Fe₂O₃]] || 2.5g/m³ ||
|| Silicon || 5 to 10%  || || [[ https://www.cdc.gov/niosh/npg/npgd0552.html | IDLH SiO₂]] || 3.0g/m³ ||
|| Boron || 1 to 5% || || [[ https://www.cdc.gov/niosh/idlh/1303862.html | IDLH B₂O₃]] || 2,0g/m³ ||
|| resistivity || 1.3 μΩ-m || ||<-2>                                     ||
||<-2>
60 Hz and 1.4 T || || Induction at 80 A/m || ≥1.35 T ||
|| Core Loss || ≤0.17 W/kg || ||Exciting Apparent Power* || 1.1 (VA/kg) ||
Line 25: Line 19:
The core loss appears proportional to (frequency × flux )² . || [[attachment:2605SA1_coreloss.jpg | {{attachment:2605SA1_coreloss.jpg}}]] || Core loss appears proportional to <<BR>><<BR>> (frequency × flux )^1.8^ .<<BR>><<BR>> Figure from datasheet. ||
Line 27: Line 21:
== Failure and oxidation ==
Line 28: Line 23:
Iron has a specific heat of 25.1 J/(mol·K), vaporizes at 3140K, and has a heat of vaporization of 340 kJ/mol . Naively, to go from 400K to vaporization requires 410 kJ/mol or 16 MJ/kg . The rotor moves at 14 km/s, the kinetic energy is 98 MJ/kg, so there is more than enough energy to vaporize the rotor foil and ignite it. '''Further study and experimentation needed'''; perhaps most of the energy will end up in the surrounding air.

Rotor Lamination

Laminated launch loop rotors will have good magnetic properties and will rapidly disperse and oxidize in the atmosphere after a rotor-release catastrophe. Worst case, thin flakes survive and cut.

Metglas 2605SA1 looks good, higher temperature than 2605HB1M. datasheet downloaded 2017/02/11

Metglas 2605SA1

Curie temperature

395C / 668K

saturation induction

1.56 Tesla

thickness

23 μm

density

7.18 g/cm³

Thermal Expansion

7.6 ppm/°C

Iron vaporization temp

3140 K

Tensile Strength

1 GPa

Elastic Modulus

100 GPa

Iron

85 to 95%

IDLH Fe₂O₃

2.5g/m³

Silicon

5 to 10%

IDLH SiO₂

3.0g/m³

Boron

1 to 5%

IDLH B₂O₃

2,0g/m³

resistivity

1.3 μΩ-m

60 Hz and 1.4 T

Induction at 80 A/m

≥1.35 T

Core Loss

≤0.17 W/kg

Exciting Apparent Power*

1.1 (VA/kg)

attachment:2605SA1_coreloss.jpg

Core loss appears proportional to

(frequency × flux )1.8 .

Figure from datasheet.

Failure and oxidation

Iron has a specific heat of 25.1 J/(mol·K), vaporizes at 3140K, and has a heat of vaporization of 340 kJ/mol . Naively, to go from 400K to vaporization requires 410 kJ/mol or 16 MJ/kg . The rotor moves at 14 km/s, the kinetic energy is 98 MJ/kg, so there is more than enough energy to vaporize the rotor foil and ignite it. Further study and experimentation needed; perhaps most of the energy will end up in the surrounding air.

RotorLamination (last edited 2017-10-21 17:03:39 by KeithLofstrom)