|| || kg/m3 || uncoated || coated ||[[ attachment:R-Rigid-Foam-SDS.pdf | Safety data sheet ]] . . . [[ https://www.generalplastics.com/wp-content/uploads/2016/11/R-Rigid-Foam-SDS.pdf | original ]] || || R-3312 || 192 || 91 || 182 || [[ attachment:r-3312-tds.pdf | data sheet]] . . . [[ https://www.generalplastics.com/wp-content/uploads/2016/11/r-3312-tds.pdf | original ]] || || R-3315 || 240 || 213 || 426 || [[ attachment:r-3315-tds.pdf | data sheet]] . . . [[ https://www.generalplastics.com/wp-content/uploads/2016/11/r-3315-tds.pdf | original ]] || || R-3318 || 288 || 244 || 487 || [[ attachment:r-3318-tds.pdf | data sheet]] . . . [[ https://www.generalplastics.com/wp-content/uploads/2016/11/r-3318-tds.pdf | original ]] || || R-3325 || 400 || 366 || 731 || [[ attachment:r-3325-tds.pdf | data sheet]] . . . [[ https://www.generalplastics.com/wp-content/uploads/2016/11/r-3325-tds.pdf | original ]] || |
|| || kg/m3 || uncoated || coated || || R-3312 || 192 || 91 || 182 || [[ attachment:r-3312-tds.pdf | data sheet]] || [[ https://www.generalplastics.com/wp-content/uploads/2016/11/r-3312-tds.pdf | original ]] || || R-3315 || 240 || 213 || 426 || [[ attachment:r-3315-tds.pdf | data sheet]] || [[ https://www.generalplastics.com/wp-content/uploads/2016/11/r-3315-tds.pdf | original ]] || || R-3318 || 288 || 244 || 487 || [[ attachment:r-3318-tds.pdf | data sheet]] || [[ https://www.generalplastics.com/wp-content/uploads/2016/11/r-3318-tds.pdf | original ]] || || R-3325 || 400 || 366 || 731 || [[ attachment:r-3325-tds.pdf | data sheet]] || [[ https://www.generalplastics.com/wp-content/uploads/2016/11/r-3325-tds.pdf | original ]] || ||<-5>[[ attachment:R-Rigid-Foam-SDS.pdf | Safety data sheet ]] || [[ https://www.generalplastics.com/wp-content/uploads/2016/11/R-Rigid-Foam-SDS.pdf | original ]] || Most of the loop will be 50 meters deep during preparation for deployment. The bottom parts of the upcurves may be 500 meters deep, and putting the floats directly on them would provide more damping than anchor cables. The turnarounds will support huge cables to to the sea floor, which will also need buoyant support. |
Plastic for Floatation
General Plastics Polyurethane Subsea Buoyancy Foam
4910 Burlington Way Tacoma WA 98409 Privately owned since 1941
Products |
Density |
Tested Depth (m) |
|||
|
kg/m3 |
uncoated |
coated |
||
R-3312 |
192 |
91 |
182 |
||
R-3315 |
240 |
213 |
426 |
||
R-3318 |
288 |
244 |
487 |
||
R-3325 |
400 |
366 |
731 |
||
Most of the loop will be 50 meters deep during preparation for deployment. The bottom parts of the upcurves may be 500 meters deep, and putting the floats directly on them would provide more damping than anchor cables. The turnarounds will support huge cables to to the sea floor, which will also need buoyant support.